Ritar Technical Advantages | Ritar R&D center gathers a large number of industry elite including two professors and a dozen senior engineers who have rich experience in battery research. Ritar also invested heavily in battery R&D technology; the performance of the batteries independently researched and developed by Ritar has met and exceeded international standards and a variety of technologies have been granted national and international patents.[More] |
R&D
Ritar R&D center gathers a large number of industry elite including two professors and a dozen senior engineers who have rich experience in renowned battery companies. Chief engineer Dr. He Degang has 50 years Battery researching experience. The R&D team was sent to top chemical university to study regular to catch up updated tech for battery.
OPZV Tubular Gel Batteries
Ritar’s core proprietary technology to improve the battery life, high-current deep cycle discharge stability during battery movement and performance.
Lead Carbon Super Battery
Ritar’s core technology, products have been identified by Shenzhen Government, The high current charge and discharge performance increased 50%, It was widely used in light electric vehicles, hybrid bus systems, power systems.
High Temperature Battery
Ritar’s core technology, a unique formula and special battery design, widely used in high-temperature area.
EV Battery
Ritar’s core technology, a unique formula and special battery design, widely used in light electric vehicles, golf carts, sightseeing cars, tourism buses, etc.
Active Substances Formula
Ritar’s core proprietary technology to improve the battery life, high-current deep cycle discharge stability during battery movement and performance. There are a number of national patent technologies.
Plate Alloy Formula
The main prolong battery life performance, deep cycle and a high-current discharge performance, there are a number of national patents technology.
Six-pole Filter Acid-Proof Seals and Technology
The pole with sealing ring, pressure ring, Plastic nut, primer, Color glue six layers of sealing structure of no leakage of acid. There are a number of national patent technologies.
Nano-silica Fibers and Hybrid Battery Cell Technology
Widely used on storage, communications, and other new energy applications, there are a number of national patent technologies.
[Retract]
| | Operation Environment and Safety | Keep batteries away from any source of ignition, organic solvent, or direct sunlight [More] | Operating Temperature Range: Max. Range: -40℃~+70℃ (See specific battery specifications) Optimal Range: 25±5℃ Relative humidity ≦ 95% Altitude ≦ 4000m Keep batteries away from any source of ignition, organic solvent, or direct sunlight; Keep the consistent ambient temperature; the temperature difference between each batteryof the same battery bank ≦3℃. [Retract] | | Installation Cautions | Match batteries into battery banks, and group the batteries of the same or similar open-circuit voltage as a bank. The voltage difference of a single cell is recommended to be a grade. [More] | ☆ Match batteries into battery banks, and group the batteries of the same or similar open-circuit voltage as abank. The voltage difference of a single cell is recommended to be a grade. ☆ Check and make sure batteries are normal, then install batteries at the predetermined location (eg a batteryrack). ☆ Do not install batteries near any heat sources (eg a transformer). ☆ Because batteries may produce flammable gas during storage, keep away from any devices with possibilityof sparks (eg a fuss) during installing. ☆ Before connection, clean battery terminals and make them shine with metallic luster. ☆ Be careful not to short-circuit battery positive and negative terminals with conductive materials. ☆ In multiple use, make sure batteries are connected correctly and then connect batteries to the chargeor load. The positive terminals should be connected with the positive of the charger or load,while negative with negative. If batteries are not connected to the charger correctly, the charge will bedamaged. Make sure there is no connection error. ☆ Connect wires tightly and make sure every connection nut and bolt is screwed down. But do not overexertto prevent damages to terminals. The recommended tightening torque is as follows. [Retract] | | Transportation and Storage | As batteries are relatively heavy, you must pay attention to the selection of the means of transportation. No rolling or throwing is allowed.[More] | ☆ As batteries are relatively heavy, you must pay attention to the selection of the means of transportation. No rolling or throwing is allowed; ☆ When carrying batteries, do not touch the terminal and safety valve; ☆ Batteries are already charged when delivered out of the factory. Therefore, you must prevent battery short circuit during transportation; ☆ Before batteries are installed, you can store them with the temperature of 0~35℃, but for no more than 6 months. Batteries that have been stored for more than 6 months must be equalizing-charged. The storage place must be clean, airy and dry; ☆ If you need to store batteries that have been used, make sure that you fully charge them before storage and then store them according to requirements. [Retract] | | Battery Maintenance | Keep the battery appearances and operating environment clean and dry.[More] | Cleaning ☆ Keep the battery appearances and operating environment clean and dry. ☆ Do not cause static when cleaning batteries. ☆ Clean batteries with a wet cloth. It's prohibited to use gasoline, alcohol or any other organic solvents to clean batteries.
Cautions ☆ Every month, recommend inspection every battery voltage. ☆ Every three months, recommend equalization charge for one time. ☆ Effect of temperature on float charge voltage: -3mV/℃/Cell. ☆ Length of service life will be directly affected by the number of discharge cycles, depth of discharge, ambient temperature and charging voltage. [Retract] | | Battery Operation Inspection and Record | Inspection and Maintenance Monthly Inspection[More] | Inspection and Maintenance 1) Monthly Inspection | Item | Content | Benchmark | Maintenance | ① The total float charge voltage of the battery bank | Inspect the voltage of the battery bank's positive and negative terminals with a voltmeter | The float charge voltage of a single cell x battery quantity | Adjust the deviation value to the benchmark value | ② Battery appearance | Inspect the battery case, lid to check wether there is leakage, blow-up, or damage | The appearance is normal | Please check the reason of the unusual appearance; and if it affects the normal use, replace the battery | Inspect whether there is dust or dirt | The appearance is clean | Clean the dust and dirt with a wet cloth | Inspect whether the connection cables and terminals get rusty | No rust | If there is rust, please clean the rust, replace the rusty connection cables, and apply rust inhibitor | ③ Connection parts | Inspect whether bolts and nuts get loose | Firm connection (see the torque table) | Tighten the loose bolts and nuts according to the requested torque | Clean the battery bank’s connection bars and terminals | No corrosion | For slight corrosion, disassemble the connection bar and immerse it in water for cleaning; for serious corrosion, change the connection bar and after cleaning the connecting points with a steel brush reconnect and tighten the new one | ④ Safety Valve | Shake the safety valve gently to check whether it is fastened securely | Firmly, no loose | If the safety valve is loose, fasten it | Check whether the safety valve is working: apply the foaming liquid around the safety valve to observe its gas | Bubbles appear periodically | It is abnormal if the safety valve is in longtime closing or opening and need to change the safety valve (and check the battery water loss condition at the same time ) | ⑤ Switch | Cut off the AC power, and switch to the UPS, power cabinet or DC power | The AC power supply switches to the power cabinet or DC power smoothly | Correct the possible deviation | | 2) Quarterly Inspection
| Item | Content | Benchmark | Maintenance | The float charge voltage of each battery | Inspect the terminal voltage of each battery in the battery bank | The float charge voltage with temperature compensation (±50mV) | If it exceeds the benchmark value, please discharge firstly and then equalizing charge and switch to float charge for 1~2 months. If it still deviates from the benchmark value, please contact us | | 3) Yearly Inspection | Item | Content | Benchmark | Maintenance | Verification discharge testing | Cut off the AC power and discharge with load; discharge 30%~40% of the rated capacity of the battery | The battery voltage should be over 1.90V/cell when discharge stops | If it is lower than the benchmark value, please discharge the battery bank firstly and then equalizing charge and then switch to float charge for 1~2 months. If it still deviates from the benchmark value, please contact us | | [Retract] | | | | | |